COVID Pandemic and the lockdown has affected economies and businesses in an unprecedented way. The disruption caused to industries has resulted in both good and bad changes depending on the segment. It this disruption permanent? What will happen post lockdown? Answer to these questions are only to be guessed at this time, but one thing that stands out is that many industries will take a while to fully recover after the lockdown gets over.

One of them is the HOTEL industry.

Part of building a resilient strategy is to take a stack on passive expenses and for-purpose businesses are looking to keep their cost in check via new solutions, new technology, and systems that would lead to more savings.

Energy costs contribute to a substantial amount, especially in the hotel industry, and saving a decent fraction of this can be a game-changer. The question is

How can you to get energy efficiency in existing properties?

Can a substantial difference be made without investing in heavy upgrades?

In this article, I am going to reveal some quick and easy to do strategies that you can apply instantly in your property and generate savings from the first month itself.

1. KNOW YOUR ENERGY PATTERN.

There is an old saying “you cannot save what is not measured”

So if you have an energy management system installed like BMS, EMS, Scada, etc, pull out the data of energy consumption area wise and hour wise. Identify the pattern of energy consumption with each department and discuss with them how they can step down and optimize.

If you don’t have any measuring system, now would be a good time to consider installing sub-metering in the electrical and water system. I would cover about sub-metering in another article.

For now, high-level industry averages can be used. 45% for HVAC, 17% for water heating, 12% for lighting, 4% for ventilation, 5% for office equipment, 8% for kitchen and refrigeration, 9% for other.

This leads us to the upcoming 4 points.

2. CREATE DYNAMIC LOAD SHEDDING PLAN

Less capacity requires lesser operational areas. That means scaling back from areas not going to be used. Building systems are usually designed in a branched configuration. With less footfall, it makes sense to shut down some areas. But which one?

Sub-Metering data provide the energy consumption department wise, floor wise, wing wise, in the common areas, etc and mapping them with dynamic footfall in your property.

There are two systems in particular that need attention: Air conditioning and Electrical. Together they constitute an average of 65% of energy consumption. Statistically, just bey monitoring these two areas results in 3% of energy saving.

Let's use an example to illustrate this.

If there are 200 rooms in a city center property. The typical layout of the property is a tower with a central corridor and rooms on both sides. The electrical system in such a case is floor wise. Now let’s assume that the air conditioning system is a central water-based chiller plant of 500 Tones capacity. The way its chillers are designed is 200T+ 200T + 100T.

Now if say out of 200 rooms, 40 rooms are unoccupied and that is equivalent to two full floors. This means that 20% of running capacity can be instantly reduced for electrical lighting and air conditioning. In the chillers, since the configuration is of diverse capacities, it is possible to shut down 20% of chiller capacity i.e. 100T.

Now the question is if its possible to do the same for other systems like kitchen, water heating etc.? This requires a similar methodology of understanding the system and how they can be scaled back.

Operationally, since 20% capacity is not operational and social distancing is in effect, can one of the restaurants be closed as well, thus curtailing the kitchen load.

3. Focus on HIGH ENERGY CENTRES for DEMAND REDUCTION

In the above example, we used a floor wise method of shut-downs.

Let's use the same numbers high rise property that due to site constraints is aligned in a north-south direction. That means half of the rooms face east, and half face western direction. Now, we all know the hottest zones in a building is the western zone. The average cooling requirement for a standard 25sq m room is 2T. The same room the faces west required 3T. So instead of going by floors, the strategy can follow energy centers and shut down high heat zones.

Let's compare the effect. From the previous example, shutting 50 rooms and corridors saved 125 tons. Shutting 50 rooms on the western side without corridors saves 150 T. By simply focusing on high energy use centers, we have reduced the demand.

Another example can be of night lights. Look that this graph of what happens then lights are left on. The use of sensors and timers can be a quick fix.

4. PLAN TO AVOID PEAK HOUR CONSUMPTION

Peak hours are designated times issued by the electricity board where the tariff rates is increased on each unit beyond a certain limit. Say electricity board charges 30% extra over 500 KVA use during the hours of 10 am to 2 pm. Using submetering and departmental/ HR planning, staggering processes to avoid in peak hours saves energy. e.g. planning laundry, or kitchen washing out of these hours, using water transfer pumps during nighttime etc.

Another area of peak is the spikes that happen due to multiple processes happening together. Notice in the graph above energy spike at around 5:30 am due to turning on the kitchen appliance like grills, ovens, etc all at one time.

Smart scheduling is a simple fix and can be done either manually or more advisable is through software. Flatter the curve of electricity use, more efficient is the system and costs less in billing.

5. Keeping a track on LEAKAGES/ ENERGY DRAINS

As a passive and active strategy, this refers to building design and operations both. Energy drain happens from broken equipment/ inefficient equipment like motors like plumbing and air conditioning, appliances from the kitchen, etc. Office equipment is also another sector of energy drain.

Energy leakage like those of cool airconditioned are from door gaps, frequent door opening, etc. are facility upkeeping areas and quick fix by repairs and change of patterns. Corridors in hot climate also show stack effect, which it fast leakage of cold heavy indoor air while opening the outside door. Also, through the double door is recommended as a long-term solution, in the short term fitting a door curtain or locking the door if it is not a fire escape is advisable.